What Z2O changes for your data center.
Power is now the ceiling on AI, and water is the next constraint. Z2O gives more of your power to compute and takes water out of cooling altogether.
A unified loop, from chip to outdoor air.
Four steps, one sealed loop: ZutaCore direct-to-chip cold plates inside, Munters SyCool heat rejection on the roof.
Liquid reaches every chip
Heat transfer fluid flows through rack manifolds to the cold plates in every server.
It boils on the chip
The fluid absorbs heat by boiling, at one constant temperature.
Vapor rises to the roof
Vapor carries the heat outdoors, largely by buoyancy and gravity. Pumps assist and add redundancy.
Outdoor air condenses it
Munters SyCool units condense the vapor with outdoor air for most of the year, with active assist on the hottest days. The liquid returns to the servers.
All IT heat is captured and cooled.
Chips evolve. The loop stays.
Z2O is fungible thermal infrastructure, built for successive silicon generations. Upgrade supported cold plates on the same loop, with no re-plumbing.
More tokens per second, per dollar, per megawatt.
More tokens per second from every megawatt secured, with less cooling infrastructure to build and operate. Where power is not the constraint, lower cooling energy reduces operating cost.
More compute, same grid.
More of a fixed grid connection goes to compute, so every megawatt you secure produces more tokens.
Less to buy and install.
Much of the mechanical plant behind a conventional liquid-cooled hall is simply not there to buy, install or commission.
Less to run.
Near-zero cooling energy, and no water to buy, treat or maintain.
What two-phase does that single-phase can’t.
Z2O boils the fluid on the chip. Single-phase only warms it. That one difference shapes the whole system.
AI operators have fought hard for every megawatt, and they should not be spending it on moving heat. Z2O takes the whole thermal stack, from the chip to the outdoor air, and collapses it into one two-phase loop. That is only possible with two-phase.
Pairing Munters SyCool with ZutaCore's two-phase loop removes the water and much of the mechanical plant that AI data centers have relied on. We are proud to be ZutaCore's launch partner and to bring the first Z2O instance to market.
One architecture. Designed to scale.
Freedom to go waterless without being tied to a single vendor over time.
*First server partner: ASRock Rack's NVIDIA HGX B300 server.
ZutaCore-defined. Partner-delivered.
ZutaCore defines the Z2O architecture, fluid and interfaces, and specialist partners deliver it. If you build heat rejection, servers, racks or modular data centers, build them for Z2O.
Brought to market with Munters.
Munters SyCool is the heat rejection in the first Z2O instance, and Munters is bringing Z2O to market with us as launch partner.
Questions we hear most.
Z2O’s unified loop is delivered with Munters SyCool, which provides the dry cooling heat rejection. Munters is our launch partner. Servers, rack integration and modular data centers come from an ecosystem of specialist partners, with more partners joining in 2027.
Over a year, the cooling system uses about 3% of the energy the IT uses. The figure is modelled on the launch reference design with Munters (ASHRAE 2026) and covers the cooling system, not total facility PUE.
No. Zero water, still liquid cooling. In the reference design, two-phase direct-to-chip cooling captures 80% of the server heat, and waterless air cooling handles the rest.
Book a meeting with the ZutaCore team. We size the building blocks to your servers, power and climate, and deliver through our partner ecosystem.
No. Cooling energy rises and falls with the outdoor temperature through the year, and 1.03 is the modelled annual figure. The model assumptions are in footnote 1.
Because Z2O is the least-risk path into the two-phase era. It runs on NVIDIA HGX B300 servers from ASRock Rack today, and a common loop supports cold-plate upgrades as chip power keeps climbing.
Z2O is a reference architecture, not a data center we sell. Each building block uses standard racks, supported vendor IT and ZutaCore cold plates (OmniTherm™ and HyperCool®), with Munters SyCool heat rejection, delivered with our partners.
No. Z2O has no cooling water in its loop or in the facility cooling path. A waterless heat transfer fluid boils on the chip and condenses in the dry coolers, in one sealed loop, with no coolant distribution unit and no facility water loop.
See what Z2O does for your site.
Book a meeting
Run your own site, power and climate through the Z2O numbers with a ZutaCore engineer.
BOOK A MEETINGReference architecture brief
The building block, the loop, the launch configuration and how it scales, in a short technical summary.
GET THE BRIEFBecome an ecosystem partner
Build heat rejection, servers, racks or modular data centers on the Z2O architecture.
BECOME A PARTNER1 Annualized pPUE 1.03, modelled on the launch reference design with Munters (ASHRAE 2026 one-pager): hour-by-hour Dulles, VA bin data, 43 °C saturation temperature, 80/20 liquid/air split, 100% IT load. In the same model, best-in-class chilled water has an annualized pPUE of 1.115; Z2O uses about a quarter of its cooling energy. Power figures per 10 MW are arithmetic on the modelled pPUE. OmniTherm™, Two-Phase Matrix Flow Boiling™ and HyperCool® are trademarks of ZutaCore, Inc. Munters® and SyCool® are registered trademarks of Munters.
Munters
Munters is a global leader in energy-efficient air treatment and climate solutions, headquartered in Sweden and founded more than 60 years ago by the inventor Carl Munters. Data center cooling is one of its priority growth areas.
Its SyCool systems use thermosiphon technology to move heat from the data center to outdoor air without water, capturing more free-cooling hours with very little energy.
As launch partner, Munters SyCool provides the heat rejection for the first Z2O instance, condensing the two-phase loop with outdoor air for most of the year.